The Triangle Tube Recall — What You Need to Know
PVC Vent Degradation and Carbon Monoxide Risk
What We Do at Every Maintenance Visit:
- Flue temperature measurement — verifying vent pipe is not being degraded by excessive heat
- Recall kit installation — updated ignition components if not already installed
- Condensate system inspection — cleaning the fire tube heat exchanger to prevent E52 errors
- Combustion analysis — CO/CO2 levels checked to verify safe operation
- Transparent lifespan assessment — honest guidance on repair vs. replacement economics
Triangle Tube Services We Offer
Annual Maintenance
Mandatory annual service for Triangle Tube — opening and cleaning the fire tube heat exchanger, flue temperature measurement, combustion analysis, and recall kit installation.
Repair & Parts
Ignition kit recall updates, pressure sensor replacement, and error code diagnosis. We carry some common Triangle Tube parts — though heat exchangers are increasingly difficult to source.
Replacement Planning
When Triangle Tube parts become unavailable, replacement with a modern Lochinvar or Navien combi-boiler is often the smarter financial decision.
Triangle Tube FAQ
What does Triangle Tube Error Code E02 mean?
E02 is a ‘Failed Ignition’ lockout — the boiler tried to light 5 times and failed. Common causes are lack of gas, a dirty spark electrode, or a clogged condensate drain. Reset the boiler once. If E02 returns immediately, you need a service call — don’t keep resetting.
What is Triangle Tube Error Code E52?
E52 indicates flue gas temperature is too high — a safety shutdown to protect the vent pipe. This usually means the heat exchanger is fouled with scale (needs cleaning) or the system pump isn’t circulating water fast enough. Annual maintenance prevents E52 — the fire tube must be opened and cleaned every year.
How does the Triangle Tube recall affect me?
If your Prestige or Solo has original PVC venting and the recall kit has not been installed, you may have a carbon monoxide risk. We check flue temperatures at every maintenance visit and can install the updated ignition kit. We also strongly recommend a CO detector wired as a boiler kill switch in all Triangle Tube homes.
Should I repair my Triangle Tube or replace it?
Honest answer: it depends on the age and what failed. If it’s over 15 years old or the heat exchanger is cracking, replacement with a Lochinvar or Navien unit is almost always the better financial decision. Heat exchangers are increasingly unavailable and expensive when found. We give you a transparent assessment either way.
What does Triangle Tube Error Code E04 mean?
E04 is ‘High Water Temperature’ — the boiler’s supply water temperature exceeded the safety limit. This typically means the system pump failed or is running too slowly, there’s an air lock preventing circulation, or the heat exchanger is so scaled that water can’t flow through fast enough. Do not keep resetting — repeated overheating cracks heat exchangers. A technician needs to check pump operation, system pressure, and heat exchanger condition.
What does Triangle Tube Error Code E09 mean?
E09 indicates a ‘Pump Failure’ — the boiler’s internal circulator pump is not running or not generating adequate flow. This is common on older Prestige units where the pump bearings wear out. Sometimes the pump is just stuck from sitting idle during summer — a technician can try freeing the impeller. If the pump has failed entirely, it needs replacement. Without circulation, the boiler cannot operate safely.
My Triangle Tube boiler is making banging or kettling noises — what’s wrong?
Banging, rumbling, or kettling sounds from a Triangle Tube boiler almost always mean the fire tube heat exchanger is fouled with scale deposits. Water trapped under the scale layer superheats and creates steam pockets that collapse violently. This is the heat exchanger telling you it desperately needs cleaning. The fire tube must be opened and descaled. If caught early, cleaning restores normal operation. If ignored, the heat exchanger can crack — and Triangle Tube heat exchangers are increasingly difficult to source. Schedule maintenance now.